prefix for ordering cylinder

RELATED FAQS

Question
Answer
The Falcon C987 cylinder can be ordered with the #27 cam as it has a similar profile to the Schlage B520-731 cam for trims after 2/28/2011.
Schlage does not offer the B250 with Primus and it cannot be ordered less cylinder.  It is possible to install a Primus cylinder as a Primus cylinder will fit into a B250 housing as long as it wa...
The Schlage B60 is a residential grade 1 deadbolt and is not available with Everest or Primus cylinders.  If Everest or Primus is needed then a commercial deadbolt will have to be used - eithe...
Effective July, 2014, there is no longer a specific modular cam part number for dogging. The Schlage modular straight cams come with two mouting holes that allow for the cams to be mounted inverted...
The Levon lever was created to initially satisfy the ADA requirements for locks, but it is too small to fit a cylinder.  The equivalent to the Levon lever on our other products is the Rhodes and Sa...
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder.  Interchangeable core and Primus are not available with this function. 
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components. 
The part number is: 1461-3071 for the door closer cylinder body.
The Schlage L9000-Series with anti-ligature trim cannot be ordered less cylinder (L cylinder suffix), but can be ordered less core (BD or J cylinder suffix). The cylinder rose dimensions change bas...
Unless otherwise specified on an order, the cam supplied on Falcon mortise cylinders will be the following: Non-IC mortise cylinder is the 5622-STD. IC mortise cylinder is the 5622-IC. Related...
Cams for other applications may be specified with no additional charge, see pricebook.
To order Von Duprin exit device reference the "Additional information/How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The Schlage ND is shipped with a driver/tailpiece when ordered with a LD, BD, or JD suffix.
Standard Schlage rim cylinders will fit a total thickness of door and projecting trim of 3 inches, this includes a minimum of 3/8" of engagement of the tailpiece into the exit device.  See ima...
For total thickness measurements larger than 3 inches see the special cylinder offerings in Pricebook.  Specify the part number and include the total thickness.  We do not offer the ...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND.You will need to contact Medeco for the cylinderSpecify a key-in-lever cylinder to fit the Schlage ND lock.They will supply a cylinde...
Order the device as 88 NL less trim. The cylinder will be mounted to the face of the door. Use templates 10156 and 40015.
We have completed our transition to the modular design and no longer have the old design.
Standard exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK option on non fire rat...