Power supply for Senior Swing

RELATED FAQS

Question
Answer
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
The Senior Swing operator has a 24VAC output , rated at 1.5 Amps.
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/9563) have a 12...
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely closed. T...
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature.  This feature is a programmable function in the control module.  The PNG settings are: Off, On, or FD (fixed)...
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...