Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units.   A low current switch is needed because … -     &nb...
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.
The 330 must be ordered as a RX330 to have the RX switch.  You can NOT add a RX to an existing dummy 330 bar.
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.
The RX switch is required to activate the ALK. The RX switch monitors the pushbar and will signal the ALK to go into alarm when the pushbar is depressed. The RX switch also allows free in...
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
For devices shipped after 8-24-2015 with motor driven:  a.       0-200 ft, use  #18 gauge wire b.      0-500 ft, use #14 gauge wir...
For Product Shipped prior to 8-24-2015 with solenoid driven:          a.       0-100 ft, use #14 Gauge Wire      b.&n...