Can you order a 1461 cylinder only?
Resolution:
The part number is: 1461-3071 for the door closer cylinder body.:
When did LCN quit making traditional potbelly style closers?
Resolution:
The LCN "Traditional" Potbelly series closer line was discontinued in 1980. Unfortunately there is no direct replacement for these old units. Would need to replace with...:
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
Can a pull side mounted 1460 open 180°
Resolution:
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.:
What are the dimensions of the SC70 footprint
Resolution:
The measurements from center line to centerline of the mounting holes are 2-3/8" x 6-3/4".:
Can the 4630/4640 cylinder only be replaced?
Resolution:
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...:
Does LCN still make a closer that has the built in smoke detector?
Resolution:
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detector...: