panic device on electrical room
”
RELATED FAQS
Question
Answer
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
Will the 6300 electric strike work with 88-F or the 88 rim panic?
Resolution:
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
Can an 18-R-L be converted to L-NL function in the field?
Resolution:
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).:
What's needed to write a door hardware specification?
Resolution:
The following items are needed for Spec Writers to write a door and hardware specification Building code being used Occupancy type or types Occupancy load for any rooms or areas of ass...:
On which closer is the fusible link arm available?
Resolution:
The Fusible Link arm is available with the 4010, 4020 and 4110 series closers. They all use the same Fusible Link arm. The UL Listing number is for the Fusible Link arms is R1943.The 4010 Series ca...:
How is a ELR or panic device wired to a Senior Swing?
Resolution:
EL devices are wired to the Senior Swing, using the P10 (761465) cable. Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...:
Can I put an old style hex dogging kit (050153) on my 99 panic device?
Resolution:
We don't recommend to use the old style hex dogging kit into the new 98/99 exit device but it would fit as long as the device is not fire rated.:
Can the 8200 power an EL panic device?
Resolution:
The 8200 can not supply the power needed on an EL dev ice. The EL device requires a Von Duprin PS914-2RS or PS914-4RL power supply or the older Von Duprin PS873-2 or PS873-4TD models.:
What is the difference between Panic Hardware and Fire Exit Hardware?
Resolution:
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device. There are some internal parts that may be different and the method it is secured to the d...: