No. The Steelcraft H-Series hurricane door does not meet the FEMA 361 guidelines. The Paladin (PW14-Series) door does meet the FEMA 361 guidelines.
No actual templates exist for this hardware. This hardware is currently only available for use on the Steelcraft Paladin series door and frame assembly and is sold as a complete package with the lo...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
The following hinges are available on Paladin series doors and frames: Butt hinges -  4 1/2", 5" or 6" ball bearing type either standard or heavy duty Continuous hinges - full mortise...
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame.
EPT power transfer preparations are not available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door a...
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
Tornado shelter applications require the use of Paladin PW14-Series doors and FP14-Series frames: Tornado shelter doors are a tested system comprising of the door, frame and hardware. ...
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...