Question
Answer
What would keep the latch bolt on a 33A device from retracting all the way when dogged?
Resolution:
Bad dogging hook on the dogging assembly could cause the 33A/35A and 98/99 exit device latch bolt not to retract completely.:
What closer can be used with Soss invisible hinges?
Resolution:
Using Soss hinges with closers can require special device and preparation locations. If you have questions on specific closer applications, please e-mail your request (including a description ...:
Will a GJ 90 overhead stop work with an LCN 4642?
Resolution:
The LCN 4642 operator can be used with a GJ90 series stop, but you will need to follow the Flush Ceiling Template for installing the 4642.:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
Can a 4040 regular mount installed on the pull side and a Glynn Johnson 90 be mounted together?
Resolution:
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template. The 4040 door closer is on the pull side of the door and the GJ 90 is ...:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.:
Can a 4110 EDA and a Glynn Johnson 100 be used together?
Resolution:
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. :