output power on senior swing

RELATED FAQS

Question
Answer
The Senior Swing operator has a 24VAC output , rated at 1.5 Amps.
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/9563) have a 12...
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely closed. T...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...