How should a Von Duprin exit device be written out for ordering?
Resolution:
To order Von Duprin exit devices, reference the "How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website. Choose "Cata...:
When were 313AN & 315AN anodized finishes changed to SP313 (695) and 622 powder coat finishes?
Resolution:
Beginning December 6, 2010, all 33A, 35A, 98 & 99 devices ordered as 313AN Anodized was furnished in SP313 (dark brown powder coat). All devices ordered as 315AN ...:
Is the Von Duprin EL option available on Von Duprin XP98 or XP99 exit devices?
Resolution:
The EL (Electrified) option is available with Von Duprin XP98/99 exit devices. To order, specify ELXP98/99 with proper trim.:
Does Von Duprin supply the 9875, 9975, 9875-F and 9975-F mortise exit devices with NL-OP trim function?
Resolution:
For night latch function with pull by others, the 98/99 series mortise exit device should be ordered as NL less trim, e.g., 9875NL-L/TRIM. We will furnish a device only, and the mortise cyl...:
Is there an Exit Alarm Retrofit Kit (EAK) for the 19 series?
Resolution:
These kits for the 19 Series were discontinued June 11th, 2012 when the updated alarm kit for the 24/25 series was released. Prior to discontinuation, it was o...:
Can the Von Duprin ALK exit alarm be ordered with hex dogging option on?
Resolution:
The standard exit alarm ALK devices are not available with dogging option. The device can be ordered through Engineering Special with dogging option on non fire exit devices. This special is o...:
Why would the 996L trim not lock or unlock when installed with 98 or 99EO?
Resolution:
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...:
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
Does the QEL retract the latch bolt and the pushpad?
Resolution:
Yes the Von Duprin QEL exit device retracts the latch bolt and pushpad. Pushpad and latch bolt stay retracted as long as power is applied to the QEL exit device. :
Can a 55 or 88 series device have a request to exit switch?
Resolution:
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...:
Does the push bar end cap come as a separate item or do you have to order the push bar kit on the 33/35A or 98/99?
Resolution:
How to order: specify devise type, size, and finish. Example: PBKIT 33A 3' US28:
What finishes should be used on exit devices near the ocean or in saltwater environments?
Resolution:
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...:
Can the CD cylinder dogging and RX switch be ordered with 33/35 or 98/99 exit device?
Resolution:
This can be done ONLY with non fire rated exit devices.: