older door replacement

RELATED FAQS

Question
Answer
Neither Dor-O-Matic or LCN manufacturers a floor closer. 
The 330 closer and parts were discontinued in early 2009. LCN does not have any parts available for the 330 series closer. The LCN 3030 Series would be the comparable closer replacement to the...
The 33/35 series can be replaced with 33A/35A with a small modification to the door.  See the template, 33A Retrofit Preparation, for the necessary modification to the door and ...
The 996L trim is the current standard trim with a break away feature built into the lever. The 994L was the original breakaway lever trim for the 98/99 series.  DISCONTINUED in mid ...
  Additional information: The 996L looks like the 992L The 996L replaced both the 994L and 992L The internal parts for the 994L and the 996L are exactly the same. The 992L prep was a li...
The 4040/4041 closers have been replaced with the 4040XP closer. The 4040XP cylinder replaces all the older versions. There are 2 cylinder "only" option's for the 4040XP series. The 4040XP-3071(...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detectors ...
The Falcon SC71 is an exact replacement for the Norton 7500. The LCN 1460 or 4040 Series closers could be used, the mounting hole pattern is different.
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder. 
Aluminum trim is not available. All of our current trim offerings are steel.
Ives does not offer anything in that same style.
CAUTION must be used in investigating this problem - In most cases, excessive field rusting of products is caused by improper storage at the jobsite. That situation must be validated prior to refus...
These references are from an old and outdated SDI 100 specification. The new specification SDI 100 ANSI A-250.8 does not contain letter designations for core material. Core constructions designat...
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft  "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
Decorative metal panels can only be attached if the panel manufacturer is UL listed in UL’s category GVUZ. All installation, sizes and hourly ratings are in accordance with that manufacturers” ...
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...
A fire rated door for 3 hours can have one glass light maximum: 100 square inches and must have an approved glass (Firelite type) Max glass size cannot exceed 12" in width or 33" in height. Wi...