Question
Answer
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
What is the difference between Panic Hardware and Fire Exit Hardware?
Resolution:
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device. There are some internal parts that may be different and the method it is secured to the d...:
Why would the 996L trim not lock or unlock when installed with 98 or 99EO?
Resolution:
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...:
How can the Von Duprin 98/9975-L with 996L classroom trim function be converted as a night latch function in field?
Resolution:
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as se...:
How do I convert the Von Duprin 360L control from nightlatch to classroom function?
Resolution:
To convert the Von Duprin 360L/TL from nightlatch to classroom or from classroom to nightlatch invert mortise cylinder cam.:
Can an 18-R-L be converted to L-NL function in the field?
Resolution:
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).:
How do you change the Von Duprin 990TP trim to NL function?
Resolution:
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...: