Question
Answer
What is the minimum and maximum door thickness for the AD and CO series locks?
Resolution:
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8". Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...:
What is the low battery threshold for the AD and CO Locks?
Resolution:
CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...:
What is the recommended Stile Size for AD and CO?
Resolution:
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.:
Why do AD Series offline locks still give a Low Coin Cell indication after I install a new coin cell?
Resolution:
The coin cell part number is CR2025 - 3 volt lithium - available at most battery or electronics stores.:
Why is the battery draining so quickly on an AD-Series lock with a Keypad ONLY (KP) credential reader?
Resolution:
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.:
What drains the AA batteries on an AD-Series lock?
Resolution:
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1) One the four (or eight) AA was inserted reversed and the rese...:
Will the Falcon MA lock fit a 1-3/8" thick door?
Resolution: