Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
maxium lite size in rated L series doors
”
RELATED FAQS
Question
Answer
What are the maximum door width and height sizes?
Resolution:
Maximum nominal (overall) single door sizes are as follows:L-Series (Laminated Door)20 Gage = 3’ 0” wide X 8’ 0” high18 Gage = 4’ 0” wide X 10’ 0” high16 Gage = 4’ 0” wide X 10’ 0” high1...:
What is the max rating available on an full glass (FG) door?
Resolution:
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...:
What are the minimum stile and rail dimensions for the L-Series door FG, FG2 & FG3?
Resolution:
The minimum stile and rail dimensions are to exposed glass are: Stiles = 6 13/16" Top Rails = 6 3/4" Center Rails = 7 1/2" Bottom Rail = 10 3/4" For high traffic and high abuse locations th...:
What is the largest diameter hole that Steelcraft can provide for viewer preps?
Resolution:
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations.Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers must ...:
Is GrainTech available fire rated?
Resolution:
GrainTech® is available with very broad fire ratings.The option of GrainTech® does not affect the fire rating of the door.Fire ratings depend on the door series, hardware and applications.For all f...:
What is the maximum glass light size on a 90 min (1 1/2 hour) fire rated door?
Resolution:
Standard listed wire glass: one (1) light with 100 in2 per door leaf max.Firelite or other appropriately listed glass:• FM maintains one (1) light with 100 in2 per door leaf max.• UL &...:
Are FM fire rated door and frame products available?
Resolution:
FM Global is an independent underwriting agency with listing, in-plant inspection, and labeling capabilities.FM fire rated doors and frames are available, however there are a minimal amount of...:
What is the maximum door size for UL fire rated doors?
Resolution:
Maximum UL Fire Rated door sizes are as follows:A-Series:4' 0" X 8' 0" single door8' 0" X 8' 0” double door or pairsB-Series4' 0" X 10' 0" single door8' 0" X 10' 0” double door or pairsCE-Series:3'...:
What is the maximum door size for ITS/WHI fire rated doors?
Resolution:
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...:
What is the maximum glass light size on a 3 hour (180 minute) fire rated door?
Resolution:
Maximum glass light sizes for 3 hour fire doors is as follows: Wire glass - not approved for use in 3 hour fire doors. Ceramic glass: UL & ITS/WH allow one (1) light with 100 square inc...:
What is the maximum size of a UL fire rated three (3) sided frame?
Resolution:
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame:4' 0" X 10' 0" single door opening8' 0" X 10' 0” double door openingMU-Series frame...:
What is the maximum size of a ITS/WHI fire rated three (3) sided frame?
Resolution:
ITS/WHI Fire Rated three (3) frames are available in the following maximum door opening sizes:F and FN-Series:4' 0" X 10' 0" single door8' 0" X 10' 0” double door or pairsMU-Series:4' 0" X 9' 0" si...:
What options are available on the CE-Series doors?
Resolution:
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, and hardware prepar...:
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
What are the thermal factors for Steelcraft door products?
Resolution:
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners) U-Factor = 0.50 R-Value = 2.01B16 Series (Steel Sti...:
Can doors be prepared for raceways in the factory?
Resolution:
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 3/4" ID steel...:
What are the standard door and frame clearances?
Resolution:
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...:
Factory installed louvers?
Resolution:
Stamped louvers are no longer available from Steelcraft in any door series. Steelcraft discontinued this offering in 2008. Steelcraft will only provide a cutout only in doors for louvers.: