low battery report

RELATED FAQS

Question
Answer
The AD lock  battery pack type can be changed following this procedure:1. Disconnect the existing battery pack2. Depress and hold the SCHLAGE button for a few seconds to drain off any residual...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
Coin cell replacement is not immediately registered by the AD200/250 firmware.
Performing a processor reset (pressing and releasing S1 on the Main PCB Assembly) will register the new coin cell.
Cycling lock power (i.e., disconnecting and reconnecting the "AA" battery pack) will register the new coin cell.
The coin cell part number is CR2025 - 3 volt lithium - available at most battery or electronics stores.
Coin cell replacement is not immediately registered by the CT5000 firmware.
Performing a processor reset (pressing and releasing the RESET button) will register the new coin cell.
Coin Cell part number is CR2025 - 3Volt Lithium - available at most any battery store.
When the battery is depleted to 6.5 volts (i.e., the Low Battery Nuisance Delay begins), a valid Normal credential will operate the lock at least 500 times before Critical Battery Level lockout occ...
Causes for AA battery drain in CO-Series LOCKS - Possible Cause Fix/Corrective Actions  One of the four AA batteries was inserted reversed and the reserved battery drains the other batteries. ...