LM Series Lock

RELATED FAQS

Question
Answer
CO Reader Modules are not individually replaceable, nor can they be swapped between locks. The inside and outside assemblies of a CO lock are a matched/mated set and cannot be swapped to change rea...
On May 1, 2013 the LM9000 lock was discontinued and replaced with the LM9300 Multipoint Lock. 
The Schlage LM9000 series lock was originally designed for use in FEMA (tornado) storm shelter openings and/or Florida Building code (hurricane) assemblies.  Doors, frames and hardware can be order...
  Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is in...
See the JD Yale Lever installation instruction HERE
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
A lock is any device which prevents access or use by requiring special knowledge or equipment. Mechanical locks are mechanical devices which secure an opening by keeping a door closed until a relea...
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
The Schlage L-Series mortise lock spindle and spring part number can be found in the Table 1.     Spindles and Springs   Part Number  Description  L283-060 Spindle and spring, 1...
THIS ITEM IS DISCONTINUED - See the related solution "Is a latch bolt monitor available with the Schlage mortise electrified locks?"Latch monitoring, or LM is available as an option on the&nbs...
When Privacy Mode is entered, the lock is secured as part of the Privacy Mode process.
When Privacy Mode is cancelled, if the lock is still within the Auto-Unlock period, the lock toggles unsecured.
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.
On May 1, 2013 the LM9000 lock was discontinued and replaced with the LM9300 Multipoint Lock. 
The LM9000 mortise lock, door with pre-assembled vertical rods, and frame all ship separately.  The soffit latch, bottom strike, and latch release will ship with the mortise lock, not the...
Please contact the Allegion Product Support Team on all questions or inquiries pertaining to hardware finishes warranties. Please send an e-mail to the applicable Product Support team:Closers_TechP...
Warranty Statement3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warranties do not apply to P...
If the error "Device does not support this action - E802" appears when trying to couple the lock, it is generally because the user is not pressing the SW1 tamper button 3 times, but instead pressin...
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times.  This will enable the lock to couple to the HHD.
This configuration is not possible as the anti-pick plate of a "DL" or "F" device center case interferes with the LM/DM switch mounted also on the center case. 
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...
1) Make sure the lock batteries are more than 4.0 volts. The USB connection will not detect or communicate with a voltage lower than 4 volts. Many times a firmware update will draw d...
2) Make sure the SUS/HHD is set to communicate using USB connection mode in SUS.  You should see the familiar USB symbol on the SUS main Screen in the bottom right corner.  If you see a S...
3) When you update with NEW firmware replacing very OLD firmware a S1 RESET is suggested after the update. This initializes all the AD-Series memory locations to the new firmware. S1 is the ...
4) Make sure the HHD-USB cable is securely inserted into the HHD and into the lockset.  
5) Inspect the HHD-USB connector(s), ensure no pins are damaged, recessed or out of alignment. If a damaged cable is found customers should see their dealer for a replacement or they can order a re...
5) If working with a CO lockset, the mechanical key switch needs to be in its "Inactive" or normal position.  Ensure the triangle alignment on the front escutcheon and that...