lever height from floor

RELATED FAQS

Question
Answer
Required top and bottom rod adjustment. Top rod possibly is adjusted too short and not lifting the rod far enough to engage the latch retention which would cause bottom rod to drag floor ...
Neither Dor-O-Matic or LCN manufacturers a floor closer. 
Auxiliary fire latch is tested only from door to door latching by Von Duprin. Some door manufacturers have tested our devices LBR and use additional fire latches to pass the fire test. Contact the ...
According to ANSI specifications for cylindrical or mortise locks: The lock strike centerline should be 40 5/16" from the bottom of the frame with the lock in relation to the strike. &...
The ANSI 156.19 standard states (in appendix A-5 Knowing Act Switches) that wall actuators are to have an installation height of a minimum of 34" and a maximum of 48" (center of the switch) of...
For 33/3549A and 98/9949 cable devices shipped from the factory AFTER 7-15-2016:The door opening height must be specified during order entry. The 33/3549A and 98/9949 cable devices are availab...
 
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...
See dimensions for LAT and LON levers from the L9000 series