Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
lcn factory adjustment
”
RELATED FAQS
Question
Answer
When did they start putting the green dial's on the 4041 closers?
Resolution:
LCN started putting on the green dials for the spring adjustment on the 4041's in 2001.:
What maintenance is required for an LCN closer?
Resolution:
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments. Monthly, quarterly, and annual visual inspections are recommended for Fire/...:
Is there adjustment limits on the regulation valves of LCN manual closers?
Resolution:
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valv...:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
What would cause a door closer to slam?
Resolution:
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...:
How do you install the LCN 9540 Senior Swing (REG) push arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install t...:
How do I set the hold open on my 4040 closer?
Resolution:
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...:
How do you install the LCN 9530 Senior Swing (STD) pull arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install...:
What is the delay time adjustment on a Delayed Action closers?
Resolution:
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...:
Can the AD-Series and CO-Series magnetic card credential readers be set to read data from different magnetic card tracks?
Resolution:
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...: