LCN closers head pressure
”
RELATED FAQS
Question
Answer
What LCN closers are available in a tri-pack mounting?
Resolution:
The 4040XP, 1260/1261, 1460/1461, 4030/4031 closers have the tri-pack mounting option when ordered with an Rw/PA or Hw/PA designation.:
Does LCN sell a coupler to stack two 4040XP closers together?
Resolution:
LCN does not recommend this type of installation, and has never sold a coupler to do this.:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...:
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
What options are available to add frame reinforcement for surface closer?
Resolution:
Steelcraft offers two optional types of reinforcements for open section header to be installed in distributor shop or in the field: Full profile sleeve; is a 14 gauge, 16" long part to fit the p...:
Warranty information on Allegion Commercial products.
Resolution:
See here for our Warranty Information. :