latch function diagram

RELATED FAQS

Question
Answer
The Schlage L-Series uses a clover leaf cam with the exception of the L9060 outside cylinder which uses a straight cam. The cam part number will depend on the type of mortise cylinder, keyway (for ...
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
Schlage used to offer a holdback cylinder 03-030 that could be used with the L9050, L9080, and L9082. The cylinder had a special 2-piece lazy cam that allowed the cam to be rotated only about 120 d...
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
Refer to table 1 for the list of Schlage AL-Series cylinders.     AL-Series Cylinder Reference Table    Function  Cylinder Mechanism   Complete Cylinder   Non-Hotel Functions  ...
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).
The B520-698 cam was designed for a Schlage IC mortise cylinder (see Figure 1) to operate a Falcon MA lock, all functions except the MA381.  There is no Schlage cylinder option ...
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
The Falcon MA-Series requires a different cam for keyed functions than its predecessor the Falcon M-Series.
 
 
We do not offer a true night latch, storeroom or ANSI "03" function with this device. (Entrance by trim when latchbolt is retracted by key. Key removable only when locked.) This function would da...
Schlage offers a comparable cam to the Yale 2160 and it will operate any Yale lock that utilizes the Yale 2160 cam.     Schlage Cams for Yale 2160  Part Number  Description  B520-7...
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder.  Interchangeable core and Primus are not available with this function. 
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components. 
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
 The 10-042 is an electric strike used for cylindrical and tubular latch sets.  VOLTAGE  24 VAC  12 VDC  AMPERAGE  0.74A 0.33A   FREQUENCY  60 HZ ...
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...