The 4040/4040XP closer mountings have the following maximum opening degree templating:
The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening.
The 4040/4040...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...
All functions except L9463 and L463:
Add L583-363 to the part number
09-509 L583-363 for the turn only or L9453 07L 626 L583-363 with a lock
The L583-363 part number is an option and can not...
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes:
Perimeter Seals – Zero #475 applies to the stop of the head and jambs.
Door bottom – Zero #367, surface applied.
Threshold ...
An anti-ligature lever and knob are available on the Schlage L9000 Series Mortise lock with a special recessed ADA complaint thumbturn and cylinder ring. When ordering, specify the S...
Discontinued in late 2012.
When ADA requirements became required, Schlage created this retrofit lever to fit existing D knobs. (Orbit, Plymouth, and Tulip knobs only).
See ...
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device. Maximum allowed force to retract the Von D...