Question
Answer
Can an additional jamb anchor be used as a base anchor on fire rated frames?
Resolution:
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...:
Can steel frames be installed after the wall board is installed in stud wall applications?
Resolution:
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc).Walls can be either wood stud or steel studUsed only for interior appl...:
What anchors are used in FEMA Tornado Resistant openings?
Resolution:
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...:
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
Why do frames rust out fast?
Resolution:
Excessive premature frame rusting is caused by improper jobsite installation practices and most likely caused by the following circumstances: :
What is the difference between the FE and DE-Series frames
Resolution:
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...:
Can "toed in" or "toed out" jambs be adjusted?
Resolution:
This condition (toed in or toed out jambs) is usually not found until the door is installed.Frames which have toed in or toed out jambs have been installed out of tolerance.It is the responsibility...:
Are adjustable base anchors provided with frames that are prepped for existing opening anchors?
Resolution:
No, an adjustable base anchor is not supplied on frames with existing opening anchors. The anchor design for use in existing masonry walls, is a pierce and dimple in the frame soffit for 3/8"...:
Can DW/K frame series be used in high traffic areas?
Resolution:
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and ...: