Question
Answer
Is there a wiring diagram for EL and Von Duprin PS914-2RS power supply?
Resolution:
Reference The 914 Installation instructions.:
Why do you need the potted circuit breaker for the Von Duprin EL device?
Resolution:
The potted circuit breaker for the Von Duprin EL device does the switching from the 16 amp pull coil on the solenoid to the .33 amp holding coil of the solenoid.:
What could cause the Von Duprin EL solenoid not to hold when mechanism cover plate is slide over the solenoid?
Resolution:
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment. You must lengthen the rod by turning the hex nut in front of the plun...:
Is the the PS914 EL wiring adapter needed for Von Duprin Chexit device?
Resolution:
The EL Wiring Adapter is not needed for a CX device.:
Can a Von Duprin EL device be converted back to mechanical?
Resolution:
An EL device can't be converted to mechanical device. If the device is not connected to the power supply, it would function mechanically but no mechanical dogging option.:
How do I add mechanical dogging to my Von Duprin EL device?
Resolution:
HD-EL (Hex Dogging Electric Latch Retraction) solenoid and plunger can be replaced with standard EL solenoid and plunger on non fire rated exit devices, but this should not be used on a daily basi...:
Is the Von Duprin EL option available on Von Duprin XP98 or XP99 exit devices?
Resolution:
The EL (Electrified) option is available with Von Duprin XP98/99 exit devices. To order, specify ELXP98/99 with proper trim.:
Does EL or QEL conversion kit for Von Duprin exit devices contain mechanism cover plate?
Resolution:
The conversion kit does not contain a new mechanism case cover plate. If a cover plate is desired, you would need the Fire or Less Dogging Cover Plate for EL/QEL conversion kit and Panic cove...:
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
Is there a Von Duprin conversion kit to change mechanical to electric latch retraction EL in the field?
Resolution: