Question
Answer
How can a TK400 be reset to factory defaults
Resolution:
If a factory default reset (FDR) is absolutely needed, you MUST temporarily replace the credential reader with another reader that has a Schlage Button. This should be rarely if ever required. T...:
Resetting a CO200 / CO250 Series Lock back to Factory Default Settings
Resolution:
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...:
Why would QEL retract and release repeatedly?
Resolution:
The following could cause the QEL device to retract and release repeatedly: If this is a vertical rod type device, the vertical rods could be adjusted too short. Check rods for dead locking, ...:
CT5000 Construction Mode
Resolution:
Creating a Master Construction Credential - From first power up or after clearing memory: Remove the CT5000 lid. Press and hold the Schlage button. Present a credential to the reader within ...: