hurricane device falcon

RELATED FAQS

Question
Answer
The Falcon Monarch 18-R-EO device can be converted in the field to the 18-R-L by purchasing three parts. The following items are required to convert the device.  812L or 816L lever tri...
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built Befo...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Primus  B520-730  B520-731  B520-2...
Falcon SZ Series Door is the economy Steelcraft commercial grade door recommended light commercial applications when architectural specification are not needed. Options: The SZ-Series door is...
The Falcon C987 cylinder can be ordered with the #27 cam as it has a similar profile to the Schlage B520-731 cam for trims after 2/28/2011.
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...
 The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device.  The 718C trim is listed in the Price Book for the 25 series  The instructions attached will give dimensional i...
Device would be ordered as a 25C-C as of June 2012.
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
Falcon 25 series is a ANSI/BHMA A156.3 Standard for Grade 1 device.
Falcon F-25 series is the UL Rated Fire Exit Hardware device is a ANSI/BHMA A156.3 Standard for Grade 1 device.
A copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site. BHMA
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series Doors...
The Falcon EL devices can be operated in a continuous duty cycle.
This option is not available as the solenoid is in the mechanism case where the dogging components would go.  An HD-EL solenoid is not available, and Special Dogging(SD) is not an option ...
The Von Duprin XP98/99 exit device is hurricane rated for single or pair doors.
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements? 3070 max flush outswing applications Zone 4 requires 120 to 170 psf.
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
Install the pinion cam at the top of the retractor per Figure 7-3 in Step 7 of 1690 Instructions.
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory. New England Door Closer may still have some older kits and can be contact...
The VR 810NL-V or VR 814NL-V is used on both the 25-R & 25-V devices.
Order the 25 device with the "HH" prefix as described in the device options in the Price Book.
The Special Von Duprin 2' door device as of 02-07-14 is now shipped with UL Panic Hardware label or UL Fire Exit Hardware label.  The 2’ devices are most commonly used in 5...
There is no EL conversion kit for a 2390, the device will need to be replaced.
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
For hurricane applications, seamless edges are available as an option: H-Series doors are available with optional seamed filled (HF) seam welded (HW) door edges. HE-Series doors are a...
The following Securitech products have been tested and approved for use on Steelcraft Paladin doors: 5300 series devices- 3 point surface and concealed devices 7300 series devices- 3 point surf...
The hex dogging key size for all Falcon-Monarch exit devices is 7/32".
Finish is not specifically stated as being covered under warranty as it is covered under defects in material and workmanship.  EXCEPTION: There is no finish warranty for Falcon products. ...
Falcon lock warranty statementIves warranty statementGlynn-Johnson warranty statementLCN closer warranty statementSchlage warranty statementSteelcraft warranty statementVon Duprin warranty statement
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...
As of Feb. 23rd 2011 Falcon RDS-2 power supply has been discontinued and no longer available.
The older ELR 17/18 device would have to replaced with a new EL-24/25 device and use the PS914 with either the 900-2RS or 900-4RL board.
The part number for 1690/1790 hex dogging shaft is shaft.101
The L-Series doors are designed for virtually all construction requirements in commercial building applications. They have also been tested and approved for uniform wind load per ASTM E330.  ...
The following hinges are available on Paladin series doors and frames: Butt hinges -  4 1/2", 5" or 6" ball bearing type either standard or heavy duty Continuous hinges - full mortise...
The "904H" is a UL Panic label that is placed on the centercase of the Falcon/Monarch Panic device.
No. The Steelcraft H-Series hurricane door does not meet the FEMA 361 guidelines. The Paladin (PW14-Series) door does meet the FEMA 361 guidelines.
Tornado shelter applications require the use of Paladin PW14-Series doors and FP14-Series frames: Tornado shelter doors are a tested system comprising of the door, frame and hardware. ...
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
The Von Duprin 9954 or KR9954 mullions are hurricane rated.
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as assemblies wit...
Falcon (19. 24, 25, and XX) parts manuals for Exits are downloadable on the