hotel lock cylinder

RELATED FAQS

Question
Answer
L9485:  Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn.  When deadbolt is thrown, all keys become ino...
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder.  Interchangeable core and Primus are not available with this function. 
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components. 
Key in lever Falcon cylinders do not work in Schlage locks.  The cylinders may fit, but there are no specific tailpieces created to operate any Schlage lock. SFIC SFIC is universal so Falcon and...
   Hotel cylinder in L9000 As long as the correct cam is used (Schlage clover), a Falcon Hotel cylinder will properly function in an L9486 hotel lock.
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is pr...
Putting a standard non-hotel cylinder in a L9485 or L9486 will change the operation of the lock to the L9480, storeroom lock with deadbolt.
Standard and Full Size I/C mortise cylinders on the L9485 and L9486, Hotel or Restroom Locks, use the concept of a ward ring to lock out all change keys once the deadbolt is thrown. Instead of a fu...
HANDINGA stop ring is installed on the right side for right hand operation and on the left side for left hand operation.  Right hand shown below.
The following document contains information on Falcon (Non I/C) Hotel Cylinders, including part numbers, key requirements and operation. Falcon Hotel Cylinders.
Refer to table 1 for the list of Schlage AL-Series cylinders.     AL-Series Cylinder Reference Table    Function  Cylinder Mechanism   Complete Cylinder   Non-Hotel Functions  ...
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...
Installers have reported that their AD-CO Series cylindrical or mortise locks will unlock whenever the outside lever is lifted.    This will occur if the outside spindle (square post) is install...
Falcon replaced its deadbolt offering in 2008 with the D100 and D200 series.  The D800 Grade 2 deadbolt was replaced by the D200 and the D400 Grade 1 deadbolt was replaced by the D100.   The new bo...
  Part compatibility (Old vs new): With the exception of the cylinder, most of the parts are neither backward nor forward compatible.  This includes the deadbolt. The cylinder mechanism for al...
The 09-900 mortise cylinder thumbturn has three handing options: right hand, left hand, and non-handed.  Handing of the cylinder is done by a check ball and spring placed in the housing a...
Also applies to the 09-900 XL12-196 mortise cylinder coin turn.
The new AL FSIC driver part number is A700-052.  This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring.  Th...
The AL lock can not be ordered to accept any competitor full size core.  The ND lock should be used in these applications.
The 7500 mortise lock should be configured for NL function as shipped not as Classroom. See figure 4-3 in E996L instructions.
Schlage now offers modular style cams to operate the Falcon MA locks.  The following part numbers are cams for all MA locks (except the MA381): L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
Price Book 72A List Price $8.10
The Schlage B and BD cylinder suffixes designate less small format interchangeable core (SFIC) cylinder prep for the lock. Any SFIC, 6-pin or 7-pin, can be inserted into the lock and will operate t...
Falcon D series deadbolts will not accept Schlage Key-in-lever cylinders. The faceplate plug hole is smaller in diameter than the Schlage plug and does not fit flush when i...
For a Schlage "C"  keyway:  Specify "CP6" as the cylinder suffix when ordering  D100 or D200 locks (All other Schlage keyways are not available).
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
The Schlage ND is shipped with a driver/tailpiece when ordered with a LD, BD, or JD suffix.
L583-446; Schlage Adams Rite MS modular cam used on 1 1/8", 1 3/8" and 1 5/8" cylinders    L583-447; Schlage Adams Rite MS modular cam used on 1 1/4", 1 1/2" and 1 3/4" cylinders  B502-944; Sch...
ND -series locks manufactured on or after January 30, 2017 use the following spring cages:Outside - N523-218 - For ALL cylinder options except for JD-YA6, JD-YA7 and JD-MEDInside - N523-222 -...
ND-series locks manufactured before January 30, 2017 used the following spring cages:
The Sargent cams listed below work for all applications except 16 inside and 50 outside.  The equivalent Sargent cam is the 13-0660. Use the B520-736 for modular cylinder lengths of 1 1/8",...
The B520-698 cam was designed for a Schlage IC mortise cylinder (see Figure 1) to operate a Falcon MA lock, all functions except the MA381.  There is no Schlage cylinder option ...
Schlage offers Falcon Retrofit cylinders to fit many of Falcon's locks.  Table 1 below contains part number for T series locks.  Table 1 - Falcon retrofit cylinders  
Standard Schlage cylinders will not fit in Yale locks, but Schlage does offer special retrofit cylinder that, when ordered, can fit into specific Yale locks.  See below for retrofit options.  ...
This is a discontinued product no longer support.  This product rights were purchased by Westinghouse, (800)-227-1667.
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
Hotel/motel lock - Deadbolt thrown or retracted by emergency master key in upper cylinder from outside or thumbturn inside. Deadlatch retracted by key in outside knob, except when the lock is in ...
The Falcon MA-Series requires a different cam for keyed functions than its predecessor the Falcon M-Series.
 
 
The full size interchangeable cores or FSIC from Schlage.
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs available vary d...
Schlage has conversion kits to convert the classroom L/LV9070 to the classroom security L/LV9071 and the classroom holdback L/LV9076 to the classroom security holdback L/LV9077.  The...
When you want to periodically disable and block access to a certain room in a building or an entrance door, that’s when you would need to use a Lockout Cylinder. See full document.
See Table below for part numbers:  
The Primus cylinders are not designed to fit into the F locks.  They are too long and the tailpiece is oriented differently.
Typically for a 1-3/4" door you would use a 1-1/4" cylinder.  Use the Table in the Pricebook for a reference:  
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructio...
Click here for a list of available Schlage cams comparable to the Sargent 13-0660.
The S-Series and S200-Series outside keyed spindle was redesigned in September 2008.   For locks manufactured BEFORE September 2008    The S and S200 lever cylinders required cy...
The Schlage L-Series uses a clover leaf cam with the exception of the L9060 outside cylinder which uses a straight cam. The cam part number will depend on the type of mortise cylinder, keyway (for ...