Question
Answer
Will a 4040 Hw/PA hold open at 180°?
Resolution:
The 4041 Rw/PA and the Hw/PA have the same template. The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...:
How much top rail is needed on a 4041 REG/PA (Rw/PA)?
Resolution:
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...:
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.:
What LCN closers are available in a tri-pack mounting?
Resolution:
The 4040XP, 1260/1261, 1460/1461, 4030/4031 closers have the tri-pack mounting option when ordered with an Rw/PA or Hw/PA designation.:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
What is the minimum top rail required on a door for 1461 Rw/PA?
Resolution:
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate. If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.:
What is the difference between a regular arm and the Rw/PA arm?
Resolution:
The Rw/PA arm is simply a regular arm that is packed with a 62PA (parallel arm) shoe, which will allow a (Tri-Pack) closer to be mounted in a regular, top jamb, or parallel arm application.: