Guard X double door strike part number
”
RELATED FAQS
Question
Answer
What strike is required when using the 2670 Guard-X on a pair of doors?
Resolution:
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike :
What is the part number for the pcb board on the 2670 Guard X exit device?
Resolution:
The following are part numbers for 2670 Guard X exit device PCB: pcb.10018 for English pcb.10019 for Spanish pcb.10020 for French:
What are the part numbers for the mounting posts and screws for an L9000 lock?
Resolution:
Mounting Posts Part Number Door Thickness L583-211 1 3/8" L583-212 1 3/4" - See note section on SL1 trim L583-213 2...:
How do I remove an X lock from the door?
Resolution:
To disassemble an X lock, remove the inside knob and unscrew the inside collar and rose. The X lock spanner wrench (012172-000-30) can be used to depress the knob catch as well as tighten/loo...:
How to replace the circuit board or horn on a Guard-X device?
Resolution:
See PCB replacement instructions below. The horn is part of the board and can only be replaced by replacing the entire board.:
Is there an electric strike that will work with the 2670 Guard X?
Resolution:
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.: