Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
glynn johnson weight
”
RELATED FAQS
Question
Answer
When sizing for a Glynn-Johnson overhead, how is a Soss hinge considered?
Resolution:
Consider the Soss hinge like a butt hinge to determine the size of overhead that is needed. For templating use the same mounting group as a 4" wide butt hinge and the appropriate door thickness.:
What is the maximum door weight recommended for LCN closers?
Resolution:
The maximum recommended door weight for LCN closers is 225 lbs.:
What is maximum width, height and weight for IVES butt hinges?
Resolution:
Butt hinges can be used on doors up to 4' wide and 200 pounds. There is no maximum door height. However, an additional hinge must be installed every 30" when exceeding a 7' d...:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
What Glynn Johnson overhead stop do I need if I want heavy duty surface mounted?
Resolution:
Either the 70, 79HD, 81 or 90 series.:
How is the 100 series from Glynn Johnson different from the 100 ADJ series?
Resolution:
The basic units are similar. The ADJ has a 12" long track that is mounted in the frame to allow the degree of opening to be selected in the field anywhere from 85 to 110 degrees, where the standar...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.:
Can I use a 4040 EDA and a Glynn Johnson 100 series concealed stop together?
Resolution:
There is not a conflict between the 4041/4040XP EDA door closer and the GJ 100 or 410 overhead concealed series stops. The exception is: the 4041/4040XP mounted on a drop plate, and the Glynn Jo...:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
Can a 4110 EDA and a Glynn Johnson 100 be used together?
Resolution:
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. :
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
Can a 4040 regular mount installed on the pull side and a Glynn Johnson 90 be mounted together?
Resolution:
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template. The 4040 door closer is on the pull side of the door and the GJ 90 is ...:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
What special template (ST) is used with a 2030 closer and GJ over head stop?
Resolution:
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...:
Will a GJ 90 overhead stop work with an LCN 4642?
Resolution:
The LCN 4642 operator can be used with a GJ90 series stop, but you will need to follow the Flush Ceiling Template for installing the 4642.:
What is the Ives invisible latch replacement for the Glynn Johnson AA, BB and AP2 latches?
Resolution:
The Ives version is the same as old Glynn-Johnson versions.: