FRAME PREP LOCATIONS
”
RELATED FAQS
Question
Answer
Where is the EPT location of a Pin-and-Barrel Continuous HInge?
Resolution:
The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...:
Can the LM9000 multi lock series be used in standard openings?
Resolution:
Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...:
Can doors be prepared for raceways in the factory?
Resolution:
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 3/4" ID steel...:
What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
Can a filler or cover plate be used to blank out a EPT prep on a fire rated frame?
Resolution:
Yes, a filler plate can be used to cover an EPT prep as long as it is made from the same material as the frame. This information can also be found in NFPA 80 under Chapter 5 for Field Modifications.:
How many compression anchors are provide per jamb on DW-Series frames?
Resolution:
For compression anchor details refer to the “ANCHORING SYSTEMS” section in the Steelcraft Tech Data Manual.Anchor Quantities: • 1 compression anchor per jamb through 9"depth • ...:
What is the replacement for the Locknetics 9100 series electric strike?
Resolution:
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes. The 6211 is used if the frame is being replaced. The 6210 is for ...:
Where is factory recommendation for location of an EPT?
Resolution:
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...: