What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
Do we have an electric strike for use w/ a mortise lock w/ deadbolt for wood frame?
Resolution:
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.:
Does Ives offer a 296G Flush Bolt?
Resolution:
The 296G is is not a model number but rather the UL listing number. This listing would be on many Ives Flush Bolts including; FB30 and FB40 series Automatic Flush Bolts FB50 and FB60 ...: