Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
Can the 8200 Series operator power a electric strike?
Resolution:
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.:
Can the 6111 electric strike be used with Falcon 25R?
Resolution:
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...:
Is there a monitor switch for the 6300 electric strike?
Resolution:
There are no optional monitor switches available for the 6300 electric strike.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...: