The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
The Falcon SC60, SC70, and SC80 series closers all use the same arm options. The SC91 series uses a different arm from the rest.
The Fusible Link arm is available with the 4010, 4020 and 4110 series closers. They all use the same Fusible Link arm. The UL Listing number is for the Fusible Link arms is R1943. The 4010 Serie...
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...
The Falcon FA arm is a non-handed arm similar to the LCN EDA arm.The Falcon FA-HO arm is a handed arm similar to the LCN HEDA arm.
When using the 4111 with a bar style coordinator MB-mounting brackets ordered from IVES are required. The brackets wrap around the coordinator to provide a surface for mounting the parallel arm ...