Fail secure not working

RELATED FAQS

Question
Answer
EL: Electrically Locked (Fail Safe), locks when power is supplied and is unlocked when there is no power. EU: Electrically Unlocked (Fail Secure), unlocks when power is supplied and is locked when...
The ND electrified motor driven locks shipping as of  March 14, 2016 has a field selectable operating mode, you can convert from EL to EU or EU to EL by flipping a switch on the chas...
The electrified ND electrified solenoid driven lock shipped prior to March 14, 2016 can be converted between fail safe (EL) and fail secure (EU) by swapping out the solenoid, sleeve,...
When Privacy Mode is entered, the lock is secured as part of the Privacy Mode process.
When Privacy Mode is cancelled, if the lock is still within the Auto-Unlock period, the lock toggles unsecured.
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.
Electrically locking and unlocking both levers (no cylinder) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows outside knob/lever ...
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
Look to see if the  "Fail Safe?UNLOCK" on communication failure is set and you have lost communication.
The "Unlock on READ" from diagnostics will clear with the next AD400 heartbeat, automatically. It will also clear with successful communication to a working access control panel. 
 If the AD-400/AD-401 is LINKED to a PIM400-TD2 and all credentials including invalid cards are granted access, the PIM400-TD2 is not communicating with the Access Control Panel, and the lock is st...
Or force a strike input to the PIM400-TD2. Short J8-1 and J8-2 (Door 1), Short J7-1 and J7-2 (Door 2) on the PIM400-TD2
Electrically locking and unlocking outside lever (no cylinder) - Outside knob/lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows outside knob/lev...
The Schlage ES-6400 Electric Strike has been rebranded to Von Duprin 6400 Series Electric Strike, making Allegion’s full electric strike portfolio Von Duprin branded.  All product feature...
Information available at:  http://us.allegion.com/products/system_components/electric_strikes/pages/mortise_cylindrical.aspxOverview, Features and Benefits, Technical Specifications, Wiring In...
Exit Lock— Electrically Unlocked (Fail Secure) with Request to Exit - The Outside Lever is the same as the ND12EU - The Inside Lever is the same ND12EU. and a micro switch attached to the chassis i...
FS, EL, Electrically Locked
All Keypad ONLY credentials with firmware versions between 2.9.2 and 2.11.0 should be updated to the latest firmware available at www.schlage,com/support.
A firmware issue with Keypad ONLY credential firmware, versions 2.9.2 through 2.11.0 and manufactured between 9-9-2010 and 1-5-2011 will exhibit poor battery life.
The Keypad ONLY credential Reader (KP) can prevent the reader from entering its low power sleep mode - with firmware versions 2.9.2 through 2.11.0
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.
  The super capacitor powers the AD300 motor to the correct power fail position, secure or unsecure, during a power fail event. When power is restored to an AD300 in the Power Fail secure ...
  Recognize the AD300 when first powered, or when recovering from a power loss, may NOT be fully functional for two minutes until the AD300 super capacitor is fully recharged. During this rec...
If the SUS has not timed out (only a few seconds), simply reconnect the USB cable. Firmware update should resume on its own.
If the SUS has timed out (after a few seconds), do the following: Reconnect the USB cable; When communication has been re-established, Select "Device Options" at the bottom of the Schlage...
For safety tips when working with Door Closers see here.
Following could cause the 900-2RS board not to operate: If 900-2RS board is not plugged into the PS914 mother board. If PS914 power supply is selected for 12VDC instead of 24VDC. If control co...
The Von Duprin 6000 series electric strike has a 12 or 24VDC solenoid with plunger, spring and impact washer as shown 6000 solenoid Make sure the solenoid spring and impact washer are not missin...
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUOvervoltage will cause the lock to shut down for approximately 5 minutes to allow the circu...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
The AD-Series locks provide screw terminals on the main PCB where hardwired power may be applied.
Use of hardwired power with any product other than the AD300, is NOT recommended.
The HHD Kit and Schlage Utility Software will not know or warn our customers about Power Fail considerations (will ALWAYS power fail AS IS) if hardpower is appied.
 EL devices are wired to the Senior Swing, using the P10 (761465) cable.  Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
That is the E996 Solenoid.  It is sold as part 050814-00.To replace the solenoid, refer to the E996L Installation instructions.The trim must be removed from the door.Verify if the tr...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...
Electrically locking and unlocking both levers (inside and outside cylinder with deadbolt) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power fail...
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...
To convert the E360L electric trim from fail safe to fail secure or vice versa you need to replace the solenoid.  The 050743 is the fail secure and 050744 is the fail safe solenoid kit.  See atta...
Electrically locking and unlocking both levers (outside cylinder, inside thumbturn with deadbolt) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (pow...
This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory Default Reset (FDR) to remove any previ...
Manually Setting the RS-485 Address This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory De...
Procedure for the L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThese devices have a selectable switch in the upper right corner of chassis.  Simply move the switch to ...
Procedure for the L9080EL/EU and L9082EL/EUTo modify an electrified L9000 from EU to EL or EL to EU move the link pin to the appropriate location indicated below in Figure 1.  
Electrically locking and unlocking both levers (inside and outside cylinders) - Both levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows outside ...
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...
The following items may cause the  PS900 series power supply to have no DC output voltage. 1. If  the DC voltage selection jumper is missing, the power supply will not provide any D...
To convert the Von Duprin 6000 series electric strikes from FS to FSE  or from FSE to FS follow these steps: Remove the electric strike face plate. Remove the strike box cover pl...
Part numbers: FS slider, part # 970387 (6211WF/6212WF/6221/6223 only) FS slider, part # 970388 (Except 6211WF/6212WF/6221/6223) FSE slider, part # 970388 (6211WF/6212WF/6221/6223 only) FSE sl...
A thumbpiece, knob or lever trim left in the unlock position would be locked when the Chexit is armed and unlock when the Chexit device is disarmed. To keep the outside trim in the lock p...
CO Reader Modules are not individually replaceable, nor can they be swapped between locks. The inside and outside assemblies of a CO lock are a matched/mated set and cannot be swapped to change rea...
FSE, EU, Electrically Unlocked
Follow these questions to determine which Von Duprin electric strike model you have 1. What type of hardware is latching to the electric strike?   2. Single or pair ...
See Catalog to identify specific model: Von Duprin Electrical Security Products and Accessories Catalog
The E996L is only shipped FS fail safe from the factory but can be converted to FSE fail secure.  To convert the 996L to E996L (fail safe or fail secure) follow step 1 of the attached installa...
The sliders are different between the 6211 and 6211WF.  The FS slider part number for the 6211 is 970388 and for the 6211WF is 970387.
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
This is not possible as an EL device is an electric latch retraction and requires power to unlock the door thus only available in Fail Secure.
The Von Duprin 6300 surface mounted electric strike is only available as Fail-Secure.