The sliders are different between the 6211 and 6211WF.  The FS slider part number for the 6211 is 970388 and for the 6211WF is 970387.
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
The ND electrified motor driven locks shipping as of  March 14, 2016 has a field selectable operating mode, you can convert from EL to EU or EU to EL by flipping a switch on the chas...
The electrified ND electrified solenoid driven lock shipped prior to March 14, 2016 can be converted between fail safe (EL) and fail secure (EU) by swapping out the solenoid, sleeve,...
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
This is not possible as an EL device is an electric latch retraction and requires power to unlock the door thus only available in Fail Secure.
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...
Procedure for the L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThese devices have a selectable switch in the upper right corner of chassis.  Simply move the switch to ...
Procedure for the L9080EL/EU and L9082EL/EUTo modify an electrified L9000 from EU to EL or EL to EU move the link pin to the appropriate location indicated below in Figure 1.