What is needed to keep the EL device retracted all day?
Resolution:
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...:
Do I have to use the 388 to get NL-OP on a 33A/35A series device?
Resolution:
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.The 33A/35A de...:
My PS914 has power but my 2RS card is not working?
Resolution:
Following could cause the 900-2RS board not to operate: If 900-2RS board is not plugged into the PS914 mother board. If PS914 power supply is selected for 12VDC instead of 24VDC. If control co...: