EU ND SERIES WIRING

RELATED FAQS

Question
Answer
Beginning March 14th, 2016, the electrified ND (ND12EL/EU; ND80EL/EU; ND96EL/EU) begin shipping with a new motor driven design which does not use an AC rectifier. (CAN NOT USE AC VOLTAGE WITH ...
The Schlage ND electrified locks can be ordered with a 3-3/4" backset, but the latch cannot be ordered separately because of UL regulations.
The ND electrified motor driven locks shipping as of  March 14, 2016 has a field selectable operating mode, you can convert from EL to EU or EU to EL by flipping a switch on the chas...
The electrified ND electrified solenoid driven lock shipped prior to March 14, 2016 can be converted between fail safe (EL) and fail secure (EU) by swapping out the solenoid, sleeve,...
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThe Schlage electrified L-Series wiring diagram can be found here and the re...
Applies to L9080EL/EU. L9082EL/EU (Discontinued)The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below. 24VAC or 24VDC (maximum 26V, ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThese models require 12/24 VDC with a peak current of 0.4 amps.  The following po...
Applies to L9080EL/EU, L9082EL/EU (Discontinued)The Schlage L9080 EU/EL and L9082 EU/EL require 24 VAC/VDC with a peak current of 1.3 Amps at 5 to 10 second intervals and a holding curren...