EU AND EL UNIVERSA

RELATED FAQS

Question
Answer
Procedure for the L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThese devices have a selectable switch in the upper right corner of chassis.  Simply move the switch to ...
Procedure for the L9080EL/EU and L9082EL/EUTo modify an electrified L9000 from EU to EL or EL to EU move the link pin to the appropriate location indicated below in Figure 1.  
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThe Schlage electrified L-Series wiring diagram can be found here and the re...
Applies to L9080EL/EU. L9082EL/EU (Discontinued)The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below. 24VAC or 24VDC (maximum 26V, ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
The ND electrified motor driven locks shipping as of  March 14, 2016 has a field selectable operating mode, you can convert from EL to EU or EU to EL by flipping a switch on the chas...
The electrified ND electrified solenoid driven lock shipped prior to March 14, 2016 can be converted between fail safe (EL) and fail secure (EU) by swapping out the solenoid, sleeve,...
EL: Electrically Locked (Fail Safe), locks when power is supplied and is unlocked when there is no power. EU: Electrically Unlocked (Fail Secure), unlocks when power is supplied and is locked when...
Electrically locking and unlocking both levers (inside and outside cylinders) - Both levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows outside ...
Electrically locking and unlocking outside lever (inside and outside cylinders) - Outside lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failure allows out...