electric strike with fob

RELATED FAQS

Question
Answer
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors. Additional Information: The Von Duprin 4854/9854 mullion is required when using 25R with 6111 electric...
 For the backset see the Falcon template above, the "B" dimension would be 3-1/4".
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
The 6300 surface mounted electric strike can be used with a 22 rim device.
A Von Duprin 6111, 6112, or 6113 electric strike will work with a 1790 device.  The 6300 will not work.
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...