Question
Answer
Can the 6111 electric strike be used with Falcon 25R?
Resolution:
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...:
What electric strike can be used with the 1790?
Resolution:
None of the Von Duprin electric strikes will work in a retrofit application where the normal standard mechanical strike is mounted to the frame because none of them are thin enough to fit in...:
Is there a monitor switch for the 6300 electric strike?
Resolution:
There are no optional monitor switches available for the 6300 electric strike.:
Can the 6300 electric strike be Fail Safe?
Resolution:
The Von Duprin 6300 surface mounted electric strike is only available as Fail-Secure.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...: