electric strike cover plate

RELATED FAQS

Question
Answer
The 4170 cover plate can be used to cover the 86 & 161 prepped doors.
Yes, a filler plate can be used to cover an EPT prep as long as it is made from the same material as the frame. This information can also be found in NFPA 80 under Chapter 5 for Field Modifications.
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment.  You must lengthen the rod by turning the hex nut in front of the plun...