electric retraction falcon

RELATED FAQS

Question
Answer
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
There is no EL conversion kit for a 2390, the device will need to be replaced.
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
 Electric latch retraction, EL, devices are only available in 24VDC.
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.  You ...
Electric Latch Retraction(ELR) option for the 19 Series was discontinued in December of 2006.