EL solenoid voltage

RELATED FAQS

Question
Answer
The part number for the solenoid for the 1690/1790/2390 is 971687-00 and for the 1490/1590 is SOLENOID.142 (which is 971687-00 with a machined bracket).  The solenoid characteristics are the s...
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...
The solenoids are different.  The current standard EL solenoid and mounting bracket is a one piece unit. The bracket is crimped into the front of the solenoid. This solenoid and plunger has no mech...
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green...
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment.  You must lengthen the rod by turning the hex nut in front of the plun...
The threaded bushing on the solenoid plunger requires 8-9 threads showing to operate correctly.
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
The 050535-00 replaces the old Von Duprin EL solenoid part number 971687.