el conversion kit fire

RELATED FAQS

Question
Answer
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
You need to order the EL98/9947 or 3'  EL conversion kit.  This will fit on 28 1/8" minimum door opening on two vertical x vertical rod device doors.
The EL retrofit kit will work with an old style 33/3547 exit device.
There is no EL conversion kit for a 2390, the device will need to be replaced.
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003).  At one time, the obsolete black EL ...
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.&n...