Answer
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
What is the minimum top rail required on a door for 1461 Rw/PA?
Resolution:
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate. If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.:
What is the difference between a 4110-18, and a 4110-18 CUSH drop plates?
Resolution:
The 4110-18, and 4110-18 CUSH drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...:
How much top rail is needed on a 4041 REG/PA (Rw/PA)?
Resolution:
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...:
What options are available on the CE-Series doors?
Resolution:
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, and hardware prepar...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.: