DPS for privacy

RELATED FAQS

Question
Answer
-On the AD series offline locks only you can change the lock function from Classroom/Storeroom to a Privacy, office or apartment function out in the field. - This is done via the HHD/SUS using...
L9496 is a Privacy mortise lock with “Occupied” Indicator. Knob/lever retracts latchbolt from either side. Deadbolt thrown or retracted by key outside (retraction by key required in the event ...
M504-271 is the emergency key used to open a locked S40.
A flat head screwdriver can be used or the 35-250 emergency key.
When Privacy Mode is entered, the lock is secured as part of the Privacy Mode process.
When Privacy Mode is cancelled, if the lock is still within the Auto-Unlock period, the lock toggles unsecured.
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
The MA indicator is available separately.  See table below for part numbers and descriptions.   Part number Trim Description Sign Functions ...
See below for visual differences between indicators.
The privacy function is activated by pressing an interior button or by throwing the deadbolt from inside. When function is engaged, user-level credentials are temporarily denied and only specified ...