door size for concealed continuous hinge

RELATED FAQS

Question
Answer
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
Steelcraft follows the industry standards for hinge reinforcement and preparation for both door and frame. Unless otherwise specified all products prepared for butt hinges will have mounting holes ...
The following hinges are available on Paladin series doors and frames: Butt hinges -  4 1/2", 5" or 6" ball bearing type either standard or heavy duty Continuous hinges - full mortise...
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft  "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...
Not specifically for lead lined doors.  But the standard hinges should work and not hit the lead lining in the door.  Since standard lead layers vary, check with door manufacturer an...
Hinge manufacturers do not require or recommend that doors should be reinforced for continuous hinges. Steelcraft does not reinforce for continuous hinges unless it is specified on the customers' P...
Doors require special downsizing for continuous hinges. The amount of downsizing depends on the hinge specified (manufacturer and type) and the hinge application (Full Mortise versus Full Surface v...
The Date Code and Closer Size are stamped in the backside of the closer body. Closer Size: If the number is "1", the closer is a 2031 or 5031. If the number is "3", the closer is a 2...
Templates for 224HD TW8 continuous hinges are  829431-00 for 83" & 85", 829433-00 for 95" & 829435-00 for 120" tall doors. Templates for 112HD TW8 continuous hinges are 829430-00 for 83" & 85", 82...
Cutout depends on the size of 224 hinge.  See 112HD/224HD-EPT template.  112HD/224HD continuous hinge  Center line of EPT to top of the door  83 inches  30 inches  85 inches  32 inc...
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the d...