door lever returns

RELATED FAQS

Question
Answer
The lever return distance (tip of lever to door face) on the Jupiter lever design is approximately 1-3/4".
This is in regards to the California State Reference Code, (Formerly Title 19, California State Fire Marshal Standard) stating that all levers with returns comply; levers must return to within 1/2"...
Issue: One or both levers don't stay horizontal and droop down.Facts: Falcon T series locks in a high use application.Cause: Weak or broken springs within the springcage.Solution: Replacement sprin...
These parts are no longer available.  For reference the spring part number is 4841 and the clip part number is 4326.
With the new FW package 2.19.0; AD300 FW 2.17.0 and AD400 FW 2.17.0 (released 09/23/2011) the firmware looks for a motor clutch switch change after a motor move command. If there is no motor clutch...
If the triangles in the spring cage spindle are not aligned properly the motor will not move enough to change the clutch switch. Is is very likely with a lock on the bench; but a properly install...
When the new firmware moves the motor three times without seeing the clutch switch change it reports to the SUS diagnostics that the motor is stalled. Aligning the triangles will let the motor move...
If the lock is mounted on the door, it is necessary to adjust the mortis/cylinder tightness and spring cage tailpiece alignments, making sure there is no binding or stopping of the spring...
Just align the triangles per the installation instructions to allow full motor movement.   - This will eliminate the SUS motor STALL report. - This will eliminate the three ...
There is potential for ND40/ND44's manufactured around March 2011 to remain locked after egress, or after the latch is depressed.  There was an issue with the keycam that created a bind when l...
The square block is probably the springcage assembly, L283-040.  This component has an internal spring to keep the lever in the horizontal position.