door does not close completely
”
RELATED FAQS
Question
Answer
What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
What does a blinking TROUBLE LED (D1/D2) mean on the PIB300?
Resolution:
3) Five blinks of the TROUBLE LED means that the AD300 on this channel has used cache mode to allow access during a communication loss with the PIB300 or the Access Control Panel. Press the LINK b...:
What does a blinking TROUBLE LED (D1/D2) mean on my PIM400-TD2?
Resolution:
a) One blink of the TROUBLE LED means the AD400 on this channel has low AA batteries. Install fresh batteries. b) Two blinks of the TROUBLE LED means the AD400 on this channel is not communicating...:
Can a door have an InPact device and glass lights?
Resolution:
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...:
How close can the top hinge be to the top of the door?
Resolution:
The minimum top and bottom butt hinge locations are as follows: To the hinge centerline: 4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...:
My COR is not allowing my inactive leaf with push side overlapping astragal to close first.
Resolution:
Astragal must be applied to pull side of active leaf, since placing the stragal on the inside of the inactive leaf will interfere with the active door closing.:
Why does the ND40 stay locked after egress?
Resolution:
There is potential for ND40/ND44's manufactured around March 2011 to remain locked after egress, or after the latch is depressed. There was an issue with the keycam that created a bind when l...: