Question
Answer
Some Access Control Panels are designed with “Supervised” or “Dry contact” requirements for the inputs and have no common ground between the ACP (Access Control Panel) and device at the door. “S...
Schlage offers the “RLBD” to support these supervised or dry contact interface applications. The "RLBD" plugs directly into the PIM400-TD2 or PIB300-TD2 for easy hook-up.  
Please reference this Tehnical Note RLBD SES-20120418 for RLBD setup, use information, hook-up diagrams and some testing suggestions when connecting to a Supervised dry contact Access Contro...
This is a link to the RLBD Installation Instructions.
This RLBD data sheet can also be found at Schlage/Technical Support. RLBD DataSheet
PIM400-485 and AD400 Two red SCHLAGE LED flashes indicates the AD400, PIM400-485 and ACP all have operational communication, and the ACP denied access with a RS-485 command. With a PIM400-485 tw...
PIM400-TD2 and AD400 Two red flashes indicates the AD400, PIM400-TD2 has radio RF communication; but the AD400 did not get a strike, GO, relay closure from the ACP. With a PIM400-TD2 TWO red fla...
  ONE red flash, One red flash indicates RF COM loss, the AD400 radio did not get an answer from the PIM400-485 radio or the PIM400-TD2 radio. The PIM400-485 will turn off it's radio if th...
The 8310-845 is now a combination "Time Delay Relay / Door Sequence" module. In 2010 the separate 8310-845 "Time Delay" module and 8310-849 “Door Sequencer” module were combined into a "common" m...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The 7982 control box will operate two door leafs maximum. Can be operated as independent, simultaneous, or in sequence (7982S).
One Deleay Egress Controller (DE5101) can run two mag locks on a pair of doors, provided the doors are not controlled independently