Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm door closers...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
Overhead Concealed door closers are used to provide a more aesthetic look to the opening.  Concealed in either the frame or the door Offer the ability to be adjusted to maintain control o...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.
LCN does not supply Allen wrenches, the size that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting regulation valves: main speed, lat...
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8” LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8” STANDARD ROD AND SHOE: ...
A  LHR (left hand reverse) door uses a RH (right hand) door closer. A RHR (right hand reverse) door uses a LH (left hand) door closer.
A door can be handed in several ways. The easiest way is to stand on the Push side of the door. Push the door away from you as if you are going to walk thru the opening. If the hinges are on yo...
To determine the hand of a door, view the door from the outside, security side or key side of door.  Once there identify which side are the hinges located on the, right or left side of t...
Go to the push side of the door opening.  See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...
Because of the new extended LCN warranties and the desire to be consistent across the entire Allegion premium brands, LCN will be moving away from offering an out-of-warranty repair service beginni...
A 1460 Pull Side can be mounted standard template for 180°, frame and trim permitting.
A 4030 Pull Side can be mounted standard template for 180°, frame and trim permitting. 
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer.  If required, handing can be verified by looking at ...
Try the steps below to improve the hold open adjustment. Remove hold open nut  Apply a couple drops of blue loctite to the threads. Re-assemble, and reset hold open. Let loctite set up overn...
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong h...
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
The 4040SE is non handed and can be mounted on the push or pull side of the door.
The 3130 Series closer is UL-10C Fire Rated for a 3 Hr. Door. The Door and Frame Manufacturer needs to be contacted to verify the Door/Frame rating would not be compromised when cutout (to prep) fo...
Product shipped on or after Feb. 8th, 2016 The "3034" and "3034H" are internal part designation that LCN uses to specify regular (3034) and hold open (3034H) roll...
On Feb 8th, 2016 - LCN launched the redesign of the Hold open clip which changed multiple components of our Track style closers, including the roller, track, hold open clip, and bumper. 
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees. ...
Surface Mounted door closers are the most durable and common type of door closer. Mounted to the surface of the door or frame Can be configured (through installation or arm type) to meet a...
For safety tips when working with Door Closers see here.
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
The "320G" is the # on a UL sticker attached to the arm of most LCN door closers, and is not a door closer model number.  The "320G" means that the arm is not a mechanical hold open device and OK t...
First you need to determine if the closer is handed.  A handed door closer will only have a single shaft on one side of the closer for the arm to attach to. If the closer is handed...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
The fluid in an LCN closer must not be refilled in the field. See attached Warranty and Repair Communication 
The maximum recommended door weight for LCN closers is 225 lbs.